{"product_id":"shelly-the-pill-analog-0-30v-add-on-measuring-sensor-403192","title":"Shelly The Pill Analog 0-30V Add-On Measuring Sensor","description":"\u003ch2\u003eShelly The Pill Analog 0-30V Add-On Measuring Sensor\u003c\/h2\u003e\n\n\u003cp\u003eThe Shelly Analog 0–30 V Add-On expands the measuring capabilities of The Pill by Shelly, allowing it to monitor compatible analogue sensors and DC voltage sources up to 30 V. Its compact design makes it a practical addition to battery-monitoring, low-voltage automation and sensor-integration projects where voltage data needs to be brought into the Shelly ecosystem.\u003c\/p\u003e\n\n\u003cp\u003eThe add-on provides one analogue input, two configurable 3.3 V digital input\/output connections and optional 5 V power terminals for compatible sensors. It requires both \u003cstrong\u003eThe Pill by Shelly\u003c\/strong\u003e and the \u003cstrong\u003eShelly 5-Terminal Add-on\u003c\/strong\u003e for operation; these products are sold separately.\u003c\/p\u003e\n\n\u003cp\u003e\u003cimg alt=\"Shelly The Pill Analog 0â€“30 V Add-On measuring module\" src=\"https:\/\/kb.shelly.cloud\/__attachments\/a_de86bf6a42cfd8c682373c8424771e239c35160ae877c64b27d618211097bf9a\/Analog%200-30V%20Add-on.jpg\"\u003e\u003c\/p\u003e\n\n\u003ch3\u003eKey Features:\u003c\/h3\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eMeasures analogue signals and DC voltage sources across a 0–30 V range.\u003c\/li\u003e\n\t\u003cli\u003eSuitable for compatible 0–5 V analogue sensors and common low-voltage battery systems.\u003c\/li\u003e\n\t\u003cli\u003eOne AN analogue input provides the connection for a sensor output or DC voltage source.\u003c\/li\u003e\n\t\u003cli\u003eTwo configurable IO2 and IO3 connections support 3.3 V logic-level digital input or output operation.\u003c\/li\u003e\n\t\u003cli\u003eOptional 5 V and ground terminals can provide power to a compatible connected sensor.\u003c\/li\u003e\n\t\u003cli\u003eCompact 36.5 × 26.5 × 11.5 mm enclosure is easy to accommodate in suitable low-voltage projects.\u003c\/li\u003e\n\t\u003cli\u003eDesigned specifically for connection to The Pill by Shelly through the separately available 5-Terminal Add-on.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eExtend Your Voltage Monitoring\u003c\/h3\u003e\n\n\u003cp\u003eThe module increases The Pill’s DC measuring range to 30 V, enabling voltage readings from compatible sensors, batteries and other low-voltage sources. Readings can then be incorporated into a Shelly-based monitoring or automation system.\u003c\/p\u003e\n\n\u003ch3\u003eAnalogue Sensor Integration\u003c\/h3\u003e\n\n\u003cp\u003eConnect compatible analogue sensors that communicate through a voltage signal, including suitable hobby sensors and professional 0–10 V devices. Depending on the sensor and system configuration, the resulting measurements can support monitoring, alerts and automated actions.\u003c\/p\u003e\n\n\u003cp\u003e\u003cimg alt=\"Shelly analogue sensor integration example\" src=\"https:\/\/www.shelly.com\/cdn\/shop\/articles\/Industrial_Analog_Sensor_Integration_bd775094-6db8-435f-ac06-04729e559236.jpg?v=1765201036\u0026amp;width=1920\"\u003e\u003c\/p\u003e\n\n\u003ch3\u003eBattery and DC Supply Monitoring\u003c\/h3\u003e\n\n\u003cp\u003eUse the add-on with The Pill by Shelly to observe supported low-voltage battery systems and DC power lines. Its 0–30 V DC range covers applications such as 4.2 V, 12 V and 24 V battery monitoring, helping you keep track of voltage changes within a compatible Shelly setup.\u003c\/p\u003e\n\n\u003cp\u003e\u003cimg alt=\"Shelly battery voltage monitoring application\" src=\"https:\/\/www.shelly.com\/cdn\/shop\/articles\/Voltage_Monitoring_for_Battery_Systems_1_e5d7f38b-24c7-4e6b-9340-d60717fc0d74.jpg?v=1765201057\u0026amp;width=1920\"\u003e\u003c\/p\u003e\n\n\u003ch3\u003eConnection Overview\u003c\/h3\u003e\n\n\u003ctable\u003e\n\t\u003cthead\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003cth bgcolor=\"#444444\" style=\"color: #ffffff;\"\u003eConnection\u003c\/th\u003e\n\t\t\t\u003cth bgcolor=\"#444444\" style=\"color: #ffffff;\"\u003eDescription\u003c\/th\u003e\n\t\t\t\u003cth bgcolor=\"#444444\" style=\"color: #ffffff;\"\u003ePurpose\u003c\/th\u003e\n\t\t\u003c\/tr\u003e\n\t\u003c\/thead\u003e\n\t\u003ctbody\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\"\u003e\n\t\t\t\u003ctd\u003e\u003cstrong\u003eGND\u003c\/strong\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003eGround\u003c\/td\u003e\n\t\t\t\u003ctd\u003eReference ground for a connected sensor or power supply\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cstrong\u003eAN\u003c\/strong\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e0–30 V analogue input\u003c\/td\u003e\n\t\t\t\u003ctd\u003eMeasures the connected analogue sensor or DC voltage source\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\"\u003e\n\t\t\t\u003ctd\u003e\u003cstrong\u003eIO2\u003c\/strong\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e3.3 V logic-level input\/output\u003c\/td\u003e\n\t\t\t\u003ctd\u003eConfigurable as a digital input or digital output\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cstrong\u003eIO3\u003c\/strong\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e3.3 V logic-level input\/output\u003c\/td\u003e\n\t\t\t\u003ctd\u003eConfigurable as a digital input or digital output\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\"\u003e\n\t\t\t\u003ctd\u003e\u003cstrong\u003e5V\u003c\/strong\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e5 V power connection\u003c\/td\u003e\n\t\t\t\u003ctd\u003ePower output for a compatible sensor or 5 V power for The Pill\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eBasic Wiring Diagram\u003c\/h3\u003e\n\n\u003cp\u003e\u003cimg alt=\"Shelly Analog 0â€“30 V Add-On basic wiring diagram\" src=\"https:\/\/kb.shelly.cloud\/__attachments\/a_879330474191964f3af9ebb905da936416177f3e172445904636c6a1a365bb86\/Analog-0-30V-Wiring.png\"\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003ePlease note:\u003c\/strong\u003e Check the terminal labels and official Shelly documentation before connecting the module. The voltage applied to the AN input must remain within the specified 0–30 V DC measuring range, while IO2 and IO3 are limited to 3.3 V logic levels.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Specifications:\u003c\/h3\u003e\n\n\u003ctable\u003e\n\t\u003cthead\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003cth bgcolor=\"#444444\" style=\"color: #ffffff;\"\u003eSpecification\u003c\/th\u003e\n\t\t\t\u003cth bgcolor=\"#444444\" style=\"color: #ffffff;\"\u003eDetails\u003c\/th\u003e\n\t\t\u003c\/tr\u003e\n\t\u003c\/thead\u003e\n\t\u003ctbody\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\"\u003e\n\t\t\t\u003ctd\u003eBrand\u003c\/td\u003e\n\t\t\t\u003ctd\u003eShelly\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eProduct Name\u003c\/td\u003e\n\t\t\t\u003ctd\u003eAnalog 0–30 V Add-on for The Pill by Shelly\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\"\u003e\n\t\t\t\u003ctd\u003eProduct Type\u003c\/td\u003e\n\t\t\t\u003ctd\u003eAnalogue and DC voltage measuring add-on\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eDC Voltmeter Range\u003c\/td\u003e\n\t\t\t\u003ctd\u003e0–30 V DC\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\"\u003e\n\t\t\t\u003ctd\u003eVoltmeter Accuracy\u003c\/td\u003e\n\t\t\t\u003ctd\u003e±(2% + 5d)\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eAnalogue Inputs\u003c\/td\u003e\n\t\t\t\u003ctd\u003e1 × AN input\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\"\u003e\n\t\t\t\u003ctd\u003eDigital Connections\u003c\/td\u003e\n\t\t\t\u003ctd\u003e2 × configurable digital inputs\/outputs: IO2 and IO3\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eDigital Logic Level\u003c\/td\u003e\n\t\t\t\u003ctd\u003e3.3 V\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\"\u003e\n\t\t\t\u003ctd\u003eDigital Input Trigger\u003c\/td\u003e\n\t\t\t\u003ctd\u003eActive LOW; low below 0.83 V and high above 2.48 V\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eMaximum Digital Input Voltage\u003c\/td\u003e\n\t\t\t\u003ctd\u003e3.3 V\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\"\u003e\n\t\t\t\u003ctd\u003eMaximum Output Switching Voltage\u003c\/td\u003e\n\t\t\t\u003ctd\u003e3.3 V logic level\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eMaximum Output Switching Current\u003c\/td\u003e\n\t\t\t\u003ctd\u003e20 mA\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\"\u003e\n\t\t\t\u003ctd\u003ePower Terminals\u003c\/td\u003e\n\t\t\t\u003ctd\u003eOptional 5 V and GND terminals\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eRequired Products\u003c\/td\u003e\n\t\t\t\u003ctd\u003eThe Pill by Shelly and Shelly 5-Terminal Add-on, sold separately\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\"\u003e\n\t\t\t\u003ctd\u003eDimensions\u003c\/td\u003e\n\t\t\t\u003ctd\u003e36.5 × 26.5 × 11.5 mm\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eWeight\u003c\/td\u003e\n\t\t\t\u003ctd\u003e8 g\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\"\u003e\n\t\t\t\u003ctd\u003eColour\u003c\/td\u003e\n\t\t\t\u003ctd\u003eBlack\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\t\t\t\u003ctd\u003e0°C to 40°C\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\"\u003e\n\t\t\t\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\t\t\t\u003ctd\u003e-20°C to 40°C\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\t\t\t\u003ctd\u003e30% to 70% relative humidity\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\"\u003e\n\t\t\t\u003ctd\u003eMaximum Altitude\u003c\/td\u003e\n\t\t\t\u003ctd\u003e2,000 m\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003eExpand your compatible Shelly monitoring project with practical 0–30 V DC measurement and add the Shelly Analog Add-On to your cart today.\u003c\/p\u003e\n","brand":"FirstShop","offers":[{"title":"Default Title","offer_id":53293675970927,"sku":"THE PILL BY SHELLY ANALOG","price":150.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0457\/5893\/9300\/files\/the-pill-by-shelly-analog-smart-home-1254164152.jpg?v=1786703830","url":"https:\/\/www.firstshop.co.za\/products\/shelly-the-pill-analog-0-30v-add-on-measuring-sensor-403192","provider":"FirstShop","version":"1.0","type":"link"}