{"product_id":"linkqnet-cat6a-flylead-lszh-cable-3m-blue-net-cat6a-3m-bl-lq-403211","title":"LinkQnet CAT6A Flylead LSZH Cable 3m Blue NET-CAT6A-3M-BL-LQ","description":"\u003ch2\u003eLinkQnet CAT6A Flylead LSZH Cable 3m Blue NET-CAT6A-3M-BL-LQ\u003c\/h2\u003e\n\n\u003cp\u003eThe NET-CAT6A-3M-BL-LQ is a 3-metre CAT6A S\/FTP shielded network flylead designed for high-speed structured cabling, rack patching and workstation connections. It combines 26AWG copper conductors with shielded twisted-pair construction to help reduce electromagnetic and signal interference, while its Low Smoke Zero Halogen jacket makes it suitable for installations where reduced smoke and halogen emissions are preferred. Gold-flashed RJ45 connectors, snagless boots and support for Gigabit and 10 Gigabit Ethernet make it a practical patch cable for modern network installations.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e3m CAT6A network flylead.\u003c\/li\u003e\n\t\u003cli\u003eS\/FTP shielded twisted-pair construction.\u003c\/li\u003e\n\t\u003cli\u003e26AWG copper conductors.\u003c\/li\u003e\n\t\u003cli\u003eLSZH Low Smoke Zero Halogen cable jacket.\u003c\/li\u003e\n\t\u003cli\u003eRJ45 8P8C connectivity.\u003c\/li\u003e\n\t\u003cli\u003eGold-flashed connector contacts.\u003c\/li\u003e\n\t\u003cli\u003eSupports Gigabit and 10 Gigabit Ethernet.\u003c\/li\u003e\n\t\u003cli\u003eSnagless connector design protects RJ45 locking clips.\u003c\/li\u003e\n\t\u003cli\u003eBlue finish for convenient cable identification.\u003c\/li\u003e\n\t\u003cli\u003e100% tested for open, short and miswire faults.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCAT6A High-Speed Networking\u003c\/h3\u003e\n\n\u003cp\u003eThe cable is rated to CAT6A specifications and is suitable for high-bandwidth Ethernet applications, including Gigabit and 10 Gigabit Ethernet. Its 3-metre length is convenient for rack-to-rack connections, patch-panel and switch connections, wall outlets and workstation networking.\u003c\/p\u003e\n\n\u003ch3\u003eS\/FTP Shielded Construction\u003c\/h3\u003e\n\n\u003cp\u003eShielded twisted-pair construction provides additional protection against electromagnetic and signal interference compared with unshielded network cabling. This makes the flylead particularly useful in structured cabling environments where multiple data and electrical cables may be routed in close proximity.\u003c\/p\u003e\n\n\u003ch3\u003e26AWG Copper Conductors\u003c\/h3\u003e\n\n\u003cp\u003eThe flylead uses 26AWG copper conductors with a specified conductor construction of 7\/0.16 ±0.008mm. This construction is designed to provide stable signal transmission while retaining the flexibility required of a network patch cable.\u003c\/p\u003e\n\n\u003ch3\u003eLSZH Cable Jacket\u003c\/h3\u003e\n\n\u003cp\u003eA Low Smoke Zero Halogen jacket is used instead of a conventional PVC jacket. LSZH material is designed to produce lower levels of smoke and halogen gases when exposed to fire, making it suitable for network installations where LSZH cabling is required or preferred.\u003c\/p\u003e\n\n\u003ch3\u003eGold-Flashed Snagless RJ45 Connectors\u003c\/h3\u003e\n\n\u003cp\u003eBoth ends use RJ45 connectivity with gold-flashed contacts for dependable network connections. Integrated snagless boots help protect the RJ45 locking clips during cable routing, installation and removal.\u003c\/p\u003e\n\n\u003ch3\u003eElectrical Testing\u003c\/h3\u003e\n\n\u003cp\u003eThe cable is specified as being 100% tested for open circuits, shorts and miswiring. Additional published electrical specifications include a maximum contact resistance of 2Ω, insulation resistance of 10MΩ and a 30V DC \/ 10ms Hi-Pot test.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003ctable width=\"100%\"\u003e\n\t\u003ctbody\u003e\n\t\t\u003ctr bgcolor=\"#444444\" data-darkreader-inline-bgcolor=\"\" style=\"--darkreader-inline-bgcolor: var(--darkreader-background-444444, #33373a);\"\u003e\n\t\t\t\u003cth width=\"38%\"\u003e\u003cfont color=\"#ffffff\" data-darkreader-inline-color=\"\" style=\"--darkreader-inline-color: var(--darkreader-text-ffffff, #e8e6e3);\"\u003eSpecification\u003c\/font\u003e\u003c\/th\u003e\n\t\t\t\u003cth\u003e\u003cfont color=\"#ffffff\" data-darkreader-inline-color=\"\" style=\"--darkreader-inline-color: var(--darkreader-text-ffffff, #e8e6e3);\"\u003eDetails\u003c\/font\u003e\u003c\/th\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\" data-darkreader-inline-bgcolor=\"\" style=\"--darkreader-inline-bgcolor: var(--darkreader-background-f2f2f2, #1f2223);\"\u003e\n\t\t\t\u003ctd\u003eProduct Code\u003c\/td\u003e\n\t\t\t\u003ctd\u003eNET-CAT6A-3M-BL-LQ\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eProduct Type\u003c\/td\u003e\n\t\t\t\u003ctd\u003eNetwork Flylead \/ Patch Cable\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\" data-darkreader-inline-bgcolor=\"\" style=\"--darkreader-inline-bgcolor: var(--darkreader-background-f2f2f2, #1f2223);\"\u003e\n\t\t\t\u003ctd\u003eCable Category\u003c\/td\u003e\n\t\t\t\u003ctd\u003eCAT6A\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eShielding\u003c\/td\u003e\n\t\t\t\u003ctd\u003eS\/FTP Shielded Twisted Pair\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\" data-darkreader-inline-bgcolor=\"\" style=\"--darkreader-inline-bgcolor: var(--darkreader-background-f2f2f2, #1f2223);\"\u003e\n\t\t\t\u003ctd\u003eCable Length\u003c\/td\u003e\n\t\t\t\u003ctd\u003e3m\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eConnector Type\u003c\/td\u003e\n\t\t\t\u003ctd\u003eRJ45 8P8C\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\" data-darkreader-inline-bgcolor=\"\" style=\"--darkreader-inline-bgcolor: var(--darkreader-background-f2f2f2, #1f2223);\"\u003e\n\t\t\t\u003ctd\u003eConductor Material\u003c\/td\u003e\n\t\t\t\u003ctd\u003eCopper\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eConductor Size\u003c\/td\u003e\n\t\t\t\u003ctd\u003e26AWG\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\" data-darkreader-inline-bgcolor=\"\" style=\"--darkreader-inline-bgcolor: var(--darkreader-background-f2f2f2, #1f2223);\"\u003e\n\t\t\t\u003ctd\u003eConductor Construction\u003c\/td\u003e\n\t\t\t\u003ctd\u003e7\/0.16 ±0.008mm\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eConnector Plating\u003c\/td\u003e\n\t\t\t\u003ctd\u003eGold Flash\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\" data-darkreader-inline-bgcolor=\"\" style=\"--darkreader-inline-bgcolor: var(--darkreader-background-f2f2f2, #1f2223);\"\u003e\n\t\t\t\u003ctd\u003eConnector Design\u003c\/td\u003e\n\t\t\t\u003ctd\u003eSnagless\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eJacket Material\u003c\/td\u003e\n\t\t\t\u003ctd\u003eLSZH (Low Smoke Zero Halogen)\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\" data-darkreader-inline-bgcolor=\"\" style=\"--darkreader-inline-bgcolor: var(--darkreader-background-f2f2f2, #1f2223);\"\u003e\n\t\t\t\u003ctd\u003eCable Diameter\u003c\/td\u003e\n\t\t\t\u003ctd\u003e6.2 ±0.20mm\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eInsulation Diameter\u003c\/td\u003e\n\t\t\t\u003ctd\u003e1.04 ±0.05mm\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\" data-darkreader-inline-bgcolor=\"\" style=\"--darkreader-inline-bgcolor: var(--darkreader-background-f2f2f2, #1f2223);\"\u003e\n\t\t\t\u003ctd\u003eEthernet Support\u003c\/td\u003e\n\t\t\t\u003ctd\u003eGigabit Ethernet \/ 10 Gigabit Ethernet\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003ePublished Cabling Standard\u003c\/td\u003e\n\t\t\t\u003ctd\u003eTIA\/EIA-568-B\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\" data-darkreader-inline-bgcolor=\"\" style=\"--darkreader-inline-bgcolor: var(--darkreader-background-f2f2f2, #1f2223);\"\u003e\n\t\t\t\u003ctd\u003eElectrical Testing\u003c\/td\u003e\n\t\t\t\u003ctd\u003e100% Open, Short and Miswire Tested\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eMaximum Contact Resistance\u003c\/td\u003e\n\t\t\t\u003ctd\u003e2Ω\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\" data-darkreader-inline-bgcolor=\"\" style=\"--darkreader-inline-bgcolor: var(--darkreader-background-f2f2f2, #1f2223);\"\u003e\n\t\t\t\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\t\t\t\u003ctd\u003e10MΩ\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eHi-Pot Test\u003c\/td\u003e\n\t\t\t\u003ctd\u003e30V DC \/ 10ms\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\" data-darkreader-inline-bgcolor=\"\" style=\"--darkreader-inline-bgcolor: var(--darkreader-background-f2f2f2, #1f2223);\"\u003e\n\t\t\t\u003ctd\u003eColour\u003c\/td\u003e\n\t\t\t\u003ctd\u003eBlue\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003ePrimary Applications\u003c\/td\u003e\n\t\t\t\u003ctd\u003eStructured Cabling, Network Racks, Patch Panels, Switches, Wall Outlets and Workstations\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWhat’s in the Box:\u003c\/h3\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e1 × NET-CAT6A-3M-BL-LQ 3m CAT6A S\/FTP LSZH Network Flylead – Blue\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThe NET-CAT6A-3M-BL-LQ provides a shielded CAT6A connection for high-speed network installations. Its 26AWG copper conductors, S\/FTP shielding, LSZH jacket, gold-flashed RJ45 connectors and snagless design make it suitable for organised structured cabling installations requiring Gigabit or 10 Gigabit Ethernet connectivity.\u003c\/p\u003e\n","brand":"FirstShop","offers":[{"title":"Default Title","offer_id":53293766181231,"sku":"NET-CAT6A-3M-BL-LQ","price":79.0,"currency_code":"ZAR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0457\/5893\/9300\/files\/net-cat6a-3m-bl-lq-ethernet-cables-1254164147.jpg?v=1786703789","url":"https:\/\/www.firstshop.co.za\/products\/linkqnet-cat6a-flylead-lszh-cable-3m-blue-net-cat6a-3m-bl-lq-403211","provider":"FirstShop","version":"1.0","type":"link"}