{"product_id":"linkqnet-1kva-xr-online-tower-ups-404251","title":"LinkQnet 1KVA XR Online Tower UPS","description":"\u003ch2\u003eLinkQnet 1KVA XR Online Tower UPS\u003c\/h2\u003e\n\n\u003cp\u003eThe LinkQnet 1kVA XR Online Tower UPS provides continuous power conditioning for compatible computers, networking hardware and other sensitive electronic equipment. Its true online double-conversion design delivers a regulated pure sine wave output with no transfer delay when moving from mains power to battery operation.\u003c\/p\u003e\n\n\u003cp\u003eThis extended-run model uses an external 24 V battery solution, allowing the battery capacity to be selected according to the required backup time. Please note that batteries are not included and must be correctly specified and installed for the intended application.\u003c\/p\u003e\n\n\u003cp\u003e\u003cimg alt=\"LinkQnet true online pure sine wave tower UPS series\" src=\"https:\/\/www.linkqage.com\/wp-content\/uploads\/2023\/11\/a3475073ad247c5364ba582e55c1cb19.jpg\"\u003e\u003c\/p\u003e\n\n\u003ch3\u003eContinuous Power Protection\u003c\/h3\u003e\n\n\u003cp\u003eOnline double-conversion technology isolates connected equipment from common mains power disturbances while maintaining a stable output. The UPS supports selectable 208, 220, 230 or 240 V output and regulates output voltage to within ±1%.\u003c\/p\u003e\n\n\u003ch3\u003eFlexible Installation and Monitoring\u003c\/h3\u003e\n\n\u003cp\u003eA wide 110–300 V AC input range helps the UPS continue operating through varying utility conditions, while generator compatibility supports alternative power arrangements. Its LCD interface displays essential operating information, including input and output values, load percentage, battery voltage, internal temperature and estimated remaining backup time.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features:\u003c\/h3\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e1,000 VA \/ 900 W capacity for compatible IT, networking and electronic equipment.\u003c\/li\u003e\n\t\u003cli\u003eTrue online double-conversion topology provides a pure sine wave output and 0 ms mains-to-battery transfer time.\u003c\/li\u003e\n\t\u003cli\u003eExtended-run design works with a separately purchased external 24 V battery solution.\u003c\/li\u003e\n\t\u003cli\u003eWide 110–300 V AC input range provides greater tolerance of fluctuating utility power.\u003c\/li\u003e\n\t\u003cli\u003eSelectable 208, 220, 230 or 240 V AC output supports different installation requirements.\u003c\/li\u003e\n\t\u003cli\u003eLCD monitoring, ECO mode, generator compatibility and cold-start capability provide flexible operation.\u003c\/li\u003e\n\t\u003cli\u003eBuilt-in protection covers short circuits, overload, overheating, battery overcharge and over-discharge, low output voltage and fan faults.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eImportant Battery Information:\u003c\/h3\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eThis UPS is supplied without batteries.\u003c\/li\u003e\n\t\u003cli\u003eA compatible external 24 V battery solution is required for backup operation.\u003c\/li\u003e\n\t\u003cli\u003eAvailable runtime depends on the connected load and the capacity and condition of the selected batteries.\u003c\/li\u003e\n\t\u003cli\u003eBattery selection and installation should be completed by a suitably qualified installer.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications:\u003c\/h3\u003e\n\n\u003ctable\u003e\n\t\u003cthead\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003cth bgcolor=\"#444444\" style=\"color: #ffffff;\"\u003eSpecification\u003c\/th\u003e\n\t\t\t\u003cth bgcolor=\"#444444\" style=\"color: #ffffff;\"\u003eDetails\u003c\/th\u003e\n\t\t\u003c\/tr\u003e\n\t\u003c\/thead\u003e\n\t\u003ctbody\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003cth bgcolor=\"#444444\" colspan=\"2\" style=\"color: #ffffff;\"\u003eGeneral\u003c\/th\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\"\u003e\n\t\t\t\u003ctd\u003eBrand\u003c\/td\u003e\n\t\t\t\u003ctd\u003eLinkQnet\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eModel\u003c\/td\u003e\n\t\t\t\u003ctd\u003e1kVA 24V XR Online Tower UPS\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\"\u003e\n\t\t\t\u003ctd\u003eSKU \/ MPN\u003c\/td\u003e\n\t\t\t\u003ctd\u003eUPS-ONL-1KVA-X-K\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eProduct Type\u003c\/td\u003e\n\t\t\t\u003ctd\u003eExtended-run online tower UPS\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\"\u003e\n\t\t\t\u003ctd\u003eTopology\u003c\/td\u003e\n\t\t\t\u003ctd\u003eOnline double conversion with full digital control\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eRated Capacity\u003c\/td\u003e\n\t\t\t\u003ctd\u003e1,000 VA \/ 900 W\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\"\u003e\n\t\t\t\u003ctd\u003eOutput Waveform\u003c\/td\u003e\n\t\t\t\u003ctd\u003ePure sine wave\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003cth bgcolor=\"#444444\" colspan=\"2\" style=\"color: #ffffff;\"\u003eInput\u003c\/th\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\"\u003e\n\t\t\t\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\t\t\t\u003ctd\u003e208 \/ 220 \/ 230 \/ 240 V AC\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\t\t\t\u003ctd\u003e110–300 V AC; 176–280 V AC at 100% load\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\"\u003e\n\t\t\t\u003ctd\u003eInput Frequency Range\u003c\/td\u003e\n\t\t\t\u003ctd\u003e40–70 Hz with 50\/60 Hz auto-sensing\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eInput Power Factor\u003c\/td\u003e\n\t\t\t\u003ctd\u003e≥0.99 with power factor correction\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003cth bgcolor=\"#444444\" colspan=\"2\" style=\"color: #ffffff;\"\u003eOutput\u003c\/th\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\"\u003e\n\t\t\t\u003ctd\u003eSelectable Output Voltage\u003c\/td\u003e\n\t\t\t\u003ctd\u003e208 \/ 220 \/ 230 \/ 240 V AC\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eOutput Power Factor\u003c\/td\u003e\n\t\t\t\u003ctd\u003e0.9\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\"\u003e\n\t\t\t\u003ctd\u003eVoltage Regulation\u003c\/td\u003e\n\t\t\t\u003ctd\u003e±1%\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eOutput Frequency — Line Mode\u003c\/td\u003e\n\t\t\t\u003ctd\u003e46–54 Hz or 56–64 Hz\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\"\u003e\n\t\t\t\u003ctd\u003eOutput Frequency — Battery Mode\u003c\/td\u003e\n\t\t\t\u003ctd\u003e50\/60 Hz ±0.1%\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eCrest Factor\u003c\/td\u003e\n\t\t\t\u003ctd\u003e3:1\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\"\u003e\n\t\t\t\u003ctd\u003eHarmonic Distortion\u003c\/td\u003e\n\t\t\t\u003ctd\u003e≤3% with a linear load; ≤5% with a non-linear load\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eAC-to-Battery Transfer Time\u003c\/td\u003e\n\t\t\t\u003ctd\u003e0 ms\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\"\u003e\n\t\t\t\u003ctd\u003eInverter-to-Bypass Transfer Time\u003c\/td\u003e\n\t\t\t\u003ctd\u003e4 ms typical\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003cth bgcolor=\"#444444\" colspan=\"2\" style=\"color: #ffffff;\"\u003eEfficiency and Battery System\u003c\/th\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\"\u003e\n\t\t\t\u003ctd\u003eAC Mode Efficiency\u003c\/td\u003e\n\t\t\t\u003ctd\u003e88%\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eBattery Mode Efficiency\u003c\/td\u003e\n\t\t\t\u003ctd\u003e85%\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\"\u003e\n\t\t\t\u003ctd\u003eBattery System Voltage\u003c\/td\u003e\n\t\t\t\u003ctd\u003e24 V DC\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eBattery Configuration\u003c\/td\u003e\n\t\t\t\u003ctd\u003eExternal battery solution required\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\"\u003e\n\t\t\t\u003ctd\u003eBatteries Included\u003c\/td\u003e\n\t\t\t\u003ctd\u003eNo\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eCold Start\u003c\/td\u003e\n\t\t\t\u003ctd\u003eSupported with a suitable connected battery system\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003cth bgcolor=\"#444444\" colspan=\"2\" style=\"color: #ffffff;\"\u003eMonitoring and Protection\u003c\/th\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\"\u003e\n\t\t\t\u003ctd\u003eLED Indicators\u003c\/td\u003e\n\t\t\t\u003ctd\u003eLine, battery, ECO and bypass modes; low battery, overload and UPS fault\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eLCD Information\u003c\/td\u003e\n\t\t\t\u003ctd\u003eInput voltage and frequency, output voltage and frequency, load percentage, battery voltage, internal temperature and estimated backup time\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\"\u003e\n\t\t\t\u003ctd\u003eStandard Communication\u003c\/td\u003e\n\t\t\t\u003ctd\u003eRS-232\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eOptional Interfaces\u003c\/td\u003e\n\t\t\t\u003ctd\u003eUSB, EPO, relay card and SNMP card\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\"\u003e\n\t\t\t\u003ctd\u003eOperating Modes\u003c\/td\u003e\n\t\t\t\u003ctd\u003eOnline, battery, bypass and ECO modes\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eProtection Functions\u003c\/td\u003e\n\t\t\t\u003ctd\u003eShort-circuit, overload, overheating, battery overcharge, battery over-discharge, low output voltage and fan fault protection\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003cth bgcolor=\"#444444\" colspan=\"2\" style=\"color: #ffffff;\"\u003eOperating Environment and Standards\u003c\/th\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\"\u003e\n\t\t\t\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\t\t\t\u003ctd\u003e0–40°C\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\t\t\t\u003ctd\u003e-25–55°C\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\"\u003e\n\t\t\t\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\t\t\t\u003ctd\u003e20–95% RH at 0–40°C, non-condensing\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\t\t\t\u003ctd\u003eUp to 1,500 m\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\"\u003e\n\t\t\t\u003ctd\u003eNoise Level\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u0026lt;50 dB at 1 m\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\t\t\t\u003ctd\u003eIEC\/EN 62040-1 and IEC\/EN 62477-1\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\"\u003e\n\t\t\t\u003ctd\u003eEMC Standards\u003c\/td\u003e\n\t\t\t\u003ctd\u003eIEC\/EN 62040-2; IEC 61000-4-2, -4-3, -4-4, -4-5, -4-6 and -4-8\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003eProtect compatible office and networking equipment with continuous online power conditioning by adding the LinkQnet 1kVA XR UPS and a correctly specified external battery solution to your setup.\u003c\/p\u003e\n","brand":"FirstShop","offers":[{"title":"Default Title","offer_id":53405525213551,"sku":"MP 1K H","price":3579.0,"currency_code":"ZAR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0457\/5893\/9300\/files\/mp-1k-h-uninterruptible-power-supply-ups-1256502679.jpg?v=1788187167","url":"https:\/\/www.firstshop.co.za\/products\/linkqnet-1kva-xr-online-tower-ups-404251","provider":"FirstShop","version":"1.0","type":"link"}