{"product_id":"commscope-cat6-u-utp-lszh-network-cable-2m-grey-npc06uzdb-gy002m-400066","title":"CommScope CAT6 U\/UTP LSZH Network Cable 2m Grey NPC06UZDB-GY002M","description":"\u003ch2\u003eCommScope NETCONNECT Cat 6 U\/UTP LSZH Network Patch Cable 2m Grey – NPC06UZDB-GY002M\u003c\/h2\u003e\n\n\u003cp\u003eThe CommScope NPC06UZDB-GY002M is a factory-terminated 2m Category 6 network patch cable for connecting compatible computers, switches, patch panels, routers, IP phones and other Ethernet equipment. It uses four unshielded twisted pairs with stranded, tin-plated copper conductors and standard RJ45 plugs at both ends. Its grey Low Smoke Zero Halogen jacket makes it suitable for structured cabling installations where reduced smoke and halogen emissions are required.\u003c\/p\u003e\n\n\u003ch3\u003eCategory 6 Network Performance\u003c\/h3\u003e\n\n\u003cp\u003eThe cable meets ANSI\/TIA Category 6 and ISO\/IEC 11801 Class E transmission requirements. It is designed for dependable Gigabit Ethernet connectivity within a correctly installed Category 6 channel, making it suitable for office networks, communications rooms, data cabinets and other structured cabling environments.\u003c\/p\u003e\n\n\u003ch3\u003eFactory-terminated RJ45 Connections\u003c\/h3\u003e\n\n\u003cp\u003eStandard RJ45 plugs are fitted to both ends, allowing the cable to connect directly between compatible network ports. Factory termination provides a convenient ready-to-use connection without requiring separate plugs, crimping tools or on-site conductor termination.\u003c\/p\u003e\n\n\u003ch3\u003eUnshielded Four-pair Construction\u003c\/h3\u003e\n\n\u003cp\u003eThe U\/UTP construction uses four individually twisted conductor pairs without an overall metallic shield. A bisector separates the pairs inside the cable to help maintain Category 6 transmission performance, while the stranded 24 AWG conductors provide the flexibility needed for patching and equipment connections.\u003c\/p\u003e\n\n\u003ch3\u003eLow Smoke Zero Halogen Jacket\u003c\/h3\u003e\n\n\u003cp\u003eThe LSZH jacket is designed to produce lower levels of smoke and halogen gases than conventional PVC materials when exposed to fire. This makes the patch cord a practical choice for applicable offices, data centres, equipment rooms and other occupied or enclosed spaces where LSZH cabling is specified.\u003c\/p\u003e\n\n\u003ch3\u003eDesigned for High-density Patching\u003c\/h3\u003e\n\n\u003cp\u003eTransparent slim-line connector boots provide a consistent appearance and help preserve access to adjacent sockets in densely populated switches and patch panels. The 2m length offers useful reach between equipment while helping limit unnecessary cable slack inside a cabinet or workspace.\u003c\/p\u003e\n\n\u003ch3\u003ePower over Ethernet Support\u003c\/h3\u003e\n\n\u003cp\u003eThe patch cord supports remote powering applications in accordance with IEEE 802.3bt Type 4 recommendations when installed according to the applicable ISO, CENELEC or TIA cabling practices. It can therefore be used with compatible Power over Ethernet devices such as wireless access points, IP phones, surveillance cameras and building-management equipment.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features:\u003c\/h3\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eCategory 6 patch cord for compatible Ethernet and structured cabling installations.\u003c\/li\u003e\n\t\u003cli\u003eTwo standard RJ45 plugs provide a ready-to-use network connection.\u003c\/li\u003e\n\t\u003cli\u003eFour-pair U\/UTP construction with flexible 24 AWG stranded conductors.\u003c\/li\u003e\n\t\u003cli\u003eTin-plated copper conductors support reliable electrical connectivity.\u003c\/li\u003e\n\t\u003cli\u003eLSZH jacket offers low-smoke, zero-halogen material characteristics.\u003c\/li\u003e\n\t\u003cli\u003eTransparent slim-line boots suit high-density switches and patch panels.\u003c\/li\u003e\n\t\u003cli\u003eSupports IEEE 802.3bt Type 4 remote-powering applications when correctly installed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications:\u003c\/h3\u003e\n\n\u003ctable\u003e\n\t\u003cthead\u003e\n\t\t\u003ctr bgcolor=\"#444444\"\u003e\n\t\t\t\u003cth style=\"color:#ffffff;font-size:14px;\"\u003eSpecification\u003c\/th\u003e\n\t\t\t\u003cth style=\"color:#ffffff;font-size:14px;\"\u003eDetails\u003c\/th\u003e\n\t\t\u003c\/tr\u003e\n\t\u003c\/thead\u003e\n\t\u003ctbody\u003e\n\t\t\u003ctr bgcolor=\"#444444\"\u003e\n\t\t\t\u003cth colspan=\"2\" style=\"color:#ffffff;font-size:14px;\"\u003eGeneral\u003c\/th\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\"\u003e\n\t\t\t\u003ctd\u003eBrand\u003c\/td\u003e\n\t\t\t\u003ctd\u003eCommScope\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003ePortfolio\u003c\/td\u003e\n\t\t\t\u003ctd\u003eNETCONNECT\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\"\u003e\n\t\t\t\u003ctd\u003eProduct Series\u003c\/td\u003e\n\t\t\t\u003ctd\u003eNPC\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eBase Model\u003c\/td\u003e\n\t\t\t\u003ctd\u003eNPC06UZDB\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\"\u003e\n\t\t\t\u003ctd\u003ePart Number\u003c\/td\u003e\n\t\t\t\u003ctd\u003eNPC06UZDB-GY002M\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eProduct Type\u003c\/td\u003e\n\t\t\t\u003ctd\u003eTwisted-pair Ethernet patch cord\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\"\u003e\n\t\t\t\u003ctd\u003eColour\u003c\/td\u003e\n\t\t\t\u003ctd\u003eGrey\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eCable Length\u003c\/td\u003e\n\t\t\t\u003ctd\u003e2m\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#444444\"\u003e\n\t\t\t\u003cth colspan=\"2\" style=\"color:#ffffff;font-size:14px;\"\u003eNetwork Classification\u003c\/th\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\"\u003e\n\t\t\t\u003ctd\u003eANSI\/TIA Category\u003c\/td\u003e\n\t\t\t\u003ctd\u003eCategory 6\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eISO\/IEC Classification\u003c\/td\u003e\n\t\t\t\u003ctd\u003eClass E\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\"\u003e\n\t\t\t\u003ctd\u003eCable Type\u003c\/td\u003e\n\t\t\t\u003ctd\u003eU\/UTP, unshielded twisted pair\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eNumber of Pairs\u003c\/td\u003e\n\t\t\t\u003ctd\u003e4\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\"\u003e\n\t\t\t\u003ctd\u003eWiring Scheme\u003c\/td\u003e\n\t\t\t\u003ctd\u003eT568B\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eSeparator Type\u003c\/td\u003e\n\t\t\t\u003ctd\u003eBisector\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#444444\"\u003e\n\t\t\t\u003cth colspan=\"2\" style=\"color:#ffffff;font-size:14px;\"\u003eConnectors and Conductors\u003c\/th\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\"\u003e\n\t\t\t\u003ctd\u003eConnector A\u003c\/td\u003e\n\t\t\t\u003ctd\u003eRJ45 plug\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eConnector B\u003c\/td\u003e\n\t\t\t\u003ctd\u003eRJ45 plug\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\"\u003e\n\t\t\t\u003ctd\u003eConnector Boot\u003c\/td\u003e\n\t\t\t\u003ctd\u003eTransparent slim-line boot\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eConductor Type\u003c\/td\u003e\n\t\t\t\u003ctd\u003eStranded\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\"\u003e\n\t\t\t\u003ctd\u003eConductor Gauge\u003c\/td\u003e\n\t\t\t\u003ctd\u003e24 AWG\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eConductor Material\u003c\/td\u003e\n\t\t\t\u003ctd\u003eTin-plated copper\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\"\u003e\n\t\t\t\u003ctd\u003eDiameter Over Jacket\u003c\/td\u003e\n\t\t\t\u003ctd\u003eApproximately 5.97mm\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#444444\"\u003e\n\t\t\t\u003cth colspan=\"2\" style=\"color:#ffffff;font-size:14px;\"\u003eElectrical Specifications\u003c\/th\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\"\u003e\n\t\t\t\u003ctd\u003eContact Resistance\u003c\/td\u003e\n\t\t\t\u003ctd\u003e20mΩ maximum\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eDC Resistance\u003c\/td\u003e\n\t\t\t\u003ctd\u003e0.3Ω maximum\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\"\u003e\n\t\t\t\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\t\t\t\u003ctd\u003e500MΩ minimum\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eCurrent Rating\u003c\/td\u003e\n\t\t\t\u003ctd\u003e1.5A at 20°C\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\"\u003e\n\t\t\t\u003ctd\u003eDielectric Withstand Voltage\u003c\/td\u003e\n\t\t\t\u003ctd\u003e1,000V AC RMS at 60Hz, contact-to-contact\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eSafety Voltage Rating\u003c\/td\u003e\n\t\t\t\u003ctd\u003e300V\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\"\u003e\n\t\t\t\u003ctd\u003eNominal Velocity of Propagation\u003c\/td\u003e\n\t\t\t\u003ctd\u003e69%\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#444444\"\u003e\n\t\t\t\u003cth colspan=\"2\" style=\"color:#ffffff;font-size:14px;\"\u003ePower over Ethernet\u003c\/th\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\"\u003e\n\t\t\t\u003ctd\u003eRemote Powering\u003c\/td\u003e\n\t\t\t\u003ctd\u003eComplies with IEEE 802.3bt Type 4 recommendations when correctly installed\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eInstallation Standards\u003c\/td\u003e\n\t\t\t\u003ctd\u003eISO\/IEC 14763-2, EN 50174-1, EN 50174-2 or TIA TSB-184-A\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#444444\"\u003e\n\t\t\t\u003cth colspan=\"2\" style=\"color:#ffffff;font-size:14px;\"\u003eEnvironmental Specifications\u003c\/th\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\"\u003e\n\t\t\t\u003ctd\u003eJacket Classification\u003c\/td\u003e\n\t\t\t\u003ctd\u003eLow Smoke Zero Halogen\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\t\t\t\u003ctd\u003e-20°C to 60°C\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\"\u003e\n\t\t\t\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\t\t\t\u003ctd\u003eUp to 93%, non-condensing\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eCPR Euroclass\u003c\/td\u003e\n\t\t\t\u003ctd\u003eDca-s2,d2,a1\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\"\u003e\n\t\t\t\u003ctd\u003eFlame Test\u003c\/td\u003e\n\t\t\t\u003ctd\u003eIEC 60332-1\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eSmoke Test\u003c\/td\u003e\n\t\t\t\u003ctd\u003eIEC 61034-2\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#444444\"\u003e\n\t\t\t\u003cth colspan=\"2\" style=\"color:#ffffff;font-size:14px;\"\u003eStandards and Compliance\u003c\/th\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\"\u003e\n\t\t\t\u003ctd\u003eTransmission Standards\u003c\/td\u003e\n\t\t\t\u003ctd\u003eANSI\/TIA-568.2-D, ISO\/IEC 11801 Class E and IEEE 802.3bt Type 4\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eEnvironmental Compliance\u003c\/td\u003e\n\t\t\t\u003ctd\u003eRoHS, UK RoHS, REACH-SVHC and China RoHS\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\"\u003e\n\t\t\t\u003ctd\u003eAdditional Compliance\u003c\/td\u003e\n\t\t\t\u003ctd\u003eRCM and ISO 9001:2015 quality-management framework\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003ePackaging Quantity\u003c\/td\u003e\n\t\t\t\u003ctd\u003e1 cable\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003eComplete a compatible structured network connection with a factory-terminated CommScope Category 6 LSZH patch cord, and add it to your cart today.\u003c\/p\u003e\n","brand":"FirstShop","offers":[{"title":"Default Title","offer_id":53254356500847,"sku":"NPC06UZDB-GY002M","price":130.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0457\/5893\/9300\/files\/npc06uzdb-gy002m-cables-accessories-1251548117.jpg?v=1785393310","url":"https:\/\/www.firstshop.co.za\/products\/commscope-cat6-u-utp-lszh-network-cable-2m-grey-npc06uzdb-gy002m-400066","provider":"FirstShop","version":"1.0","type":"link"}