{"product_id":"chint-ouvr-1-80a-3p-n-ac-over-and-under-voltage-protector-ouvr-1-80a-3p-n-be-409701","title":"Chint OUVR-1 80A 3P+N AC Over and Under Voltage Protector OUVR-1\/80A-3P+N-BE","description":"\u003ch2\u003eChint OUVR-1 80A 3P+N AC Over and Under Voltage Protector OUVR-1\/80A-3P+N-BE\u003c\/h2\u003e\n\n\u003cp\u003eThe CHINT OUVR-1 80A 3P+N Over and Under Voltage Protector is designed to monitor compatible three-phase electrical supplies and automatically disconnect the load when voltage moves outside its specified operating range. Once supply voltage returns to an acceptable level, the unit automatically reconnects after its built-in delay period, helping protect connected electrical equipment from abnormal voltage conditions.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eOvervoltage Protection:\u003c\/strong\u003e Disconnects the connected load when the monitored voltage exceeds the specified threshold.\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eUndervoltage Protection:\u003c\/strong\u003e Disconnects the circuit when voltage falls below the specified operating threshold.\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eAutomatic Recovery:\u003c\/strong\u003e Reconnects the load automatically after voltage returns to an acceptable range and the delay period has elapsed.\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003e80A Rated Current:\u003c\/strong\u003e Designed for compatible circuits with rated operating current up to 80A.\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003e3P+N Configuration:\u003c\/strong\u003e Designed for compatible three-phase plus neutral electrical systems.\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eLED Status Indication:\u003c\/strong\u003e Provides visual indication of normal and abnormal voltage conditions.\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eWide Operating Temperature:\u003c\/strong\u003e Designed to operate across a broad environmental temperature range.\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eDIN-Rail Mounting:\u003c\/strong\u003e Suitable for installation in compatible electrical distribution equipment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eThree-phase residential installations\u003c\/li\u003e\n\t\u003cli\u003eCommercial electrical distribution\u003c\/li\u003e\n\t\u003cli\u003eLight industrial systems\u003c\/li\u003e\n\t\u003cli\u003eProtection of voltage-sensitive equipment\u003c\/li\u003e\n\t\u003cli\u003eDistribution boards requiring automatic voltage monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\n\u003cp\u003eDesigned for compatible AC 230\/400V, 50Hz three-phase plus neutral systems. Installation, cable sizing and protective coordination must be performed by a suitably qualified electrical professional.\u003c\/p\u003e\n\n\u003ch3\u003eWhat's in the Box\u003c\/h3\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e1 x CHINT OUVR-1 80A 3P+N Over and Under Voltage Protector\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n\t\u003ctbody\u003e\n\t\t\u003ctr style=\"background-color: rgb(242, 242, 242);\"\u003e\n\t\t\t\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221);\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\t\t\t\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221);\"\u003eChint\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr style=\"background-color: rgb(255, 255, 255);\"\u003e\n\t\t\t\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221);\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\t\t\t\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221);\"\u003eOUVR-1\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr style=\"background-color: rgb(242, 242, 242);\"\u003e\n\t\t\t\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221);\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\t\t\t\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221);\"\u003eSelf-Recovery Overvoltage and Undervoltage Protector\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr style=\"background-color: rgb(255, 255, 255);\"\u003e\n\t\t\t\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221);\"\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\t\t\t\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221);\"\u003e3P+N\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr style=\"background-color: rgb(242, 242, 242);\"\u003e\n\t\t\t\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221);\"\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\t\t\t\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221);\"\u003e80A\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr style=\"background-color: rgb(255, 255, 255);\"\u003e\n\t\t\t\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221);\"\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\t\t\t\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221);\"\u003eAC 230\/400V\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr style=\"background-color: rgb(242, 242, 242);\"\u003e\n\t\t\t\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221);\"\u003e\u003cstrong\u003eRated Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\t\t\t\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221);\"\u003e50Hz\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr style=\"background-color: rgb(255, 255, 255);\"\u003e\n\t\t\t\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221);\"\u003e\u003cstrong\u003eOvervoltage Cut-Off\u003c\/strong\u003e\u003c\/td\u003e\n\t\t\t\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221);\"\u003e270V ±5V\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr style=\"background-color: rgb(242, 242, 242);\"\u003e\n\t\t\t\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221);\"\u003e\u003cstrong\u003eOvervoltage Recovery Range\u003c\/strong\u003e\u003c\/td\u003e\n\t\t\t\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221);\"\u003e240V to 260V\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr style=\"background-color: rgb(255, 255, 255);\"\u003e\n\t\t\t\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221);\"\u003e\u003cstrong\u003eUndervoltage Cut-Off\u003c\/strong\u003e\u003c\/td\u003e\n\t\t\t\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221);\"\u003e170V ±5V\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr style=\"background-color: rgb(242, 242, 242);\"\u003e\n\t\t\t\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221);\"\u003e\u003cstrong\u003eUndervoltage Recovery Range\u003c\/strong\u003e\u003c\/td\u003e\n\t\t\t\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221);\"\u003e185V to 195V\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr style=\"background-color: rgb(255, 255, 255);\"\u003e\n\t\t\t\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221);\"\u003e\u003cstrong\u003eReconnection Delay\u003c\/strong\u003e\u003c\/td\u003e\n\t\t\t\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221);\"\u003e30 ±10 Seconds\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr style=\"background-color: rgb(242, 242, 242);\"\u003e\n\t\t\t\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221);\"\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\t\t\t\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221);\"\u003eLess than 2W\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr style=\"background-color: rgb(255, 255, 255);\"\u003e\n\t\t\t\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221);\"\u003e\u003cstrong\u003eImpulse Withstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\t\t\t\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221);\"\u003e4kV\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr style=\"background-color: rgb(242, 242, 242);\"\u003e\n\t\t\t\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221);\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\t\t\t\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221);\"\u003e-20°C to +65°C\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr style=\"background-color: rgb(255, 255, 255);\"\u003e\n\t\t\t\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221);\"\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n\t\t\t\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221);\"\u003eTH35-7.5 DIN Rail\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr style=\"background-color: rgb(242, 242, 242);\"\u003e\n\t\t\t\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221);\"\u003e\u003cstrong\u003eConnection Orientation\u003c\/strong\u003e\u003c\/td\u003e\n\t\t\t\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221);\"\u003eBottom Entry Variant\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr style=\"background-color: rgb(255, 255, 255);\"\u003e\n\t\t\t\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221);\"\u003e\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\t\t\t\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221);\"\u003eOUVR-1\/80A-3P+N-BE\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"FirstShop","offers":[{"title":"Default Title","offer_id":68006356615535,"sku":"OUVR-1\/80A-3P+N-BE","price":1150.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0457\/5893\/9300\/files\/ouvr-1-80a-3p-n-be-power-adapters-inverters-1265685048.jpg?v=1793703331","url":"https:\/\/www.firstshop.co.za\/products\/chint-ouvr-1-80a-3p-n-ac-over-and-under-voltage-protector-ouvr-1-80a-3p-n-be-409701","provider":"FirstShop","version":"1.0","type":"link"}