{"product_id":"apc-ap6015a-8-ac-outlet-0u-1u-pdu-406365","title":"APC AP6015A 8 AC Outlet 0U\/1U PDU","description":"\u003ch2\u003eAPC AP6015A 8 AC Outlet 0U\/1U PDU\u003c\/h2\u003e\n\n\u003cp\u003eThe APC NetShelter Basic Rack PDU AP6015A is a reliable rack power distribution unit designed to distribute power to servers, networking equipment and other rack-mounted IT devices. It provides eight IEC 60320 C13 outlets and supports flexible 0U vertical or 1U horizontal rack installation. With a 2.5-metre power cord and IEC 60320 C14 input connection, the AP6015A provides a straightforward power distribution solution for data centres, server rooms and network cabinets.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\n\u003cstrong\u003e8 × IEC C13 Outlets:\u003c\/strong\u003e Provides eight output connections for compatible rack-mounted IT equipment.\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eFlexible Rack Installation:\u003c\/strong\u003e Supports both 0U vertical and 1U horizontal mounting.\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eBasic Rack PDU:\u003c\/strong\u003e Provides dependable power distribution without network monitoring or switched outlet functionality.\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eWide Input Voltage:\u003c\/strong\u003e Supports nominal input voltages including 120 V, 208 V and 230 V.\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eIEC C14 Input:\u003c\/strong\u003e Equipped with an IEC 60320 C14 input connection for convenient integration with compatible power sources and UPS systems.\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003e2.5 m Power Cord:\u003c\/strong\u003e Provides installation flexibility within racks and enclosures.\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eRack Optimised:\u003c\/strong\u003e Compact design helps distribute power without unnecessarily occupying valuable rack space when installed vertically.\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eResettable Circuit Breaker:\u003c\/strong\u003e Includes overload protection for safer rack power distribution.\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eNetShelter Compatibility:\u003c\/strong\u003e Designed for deployment with APC NetShelter racks and other compatible rack enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cimg src=\"https:\/\/www.lockstok.com\/\/ProductImages\/APC\/F1224C0D-CE2F-46DC-8A33-6D449AF2E2E7_428501.jpg?1789634465813\"\u003e\u003c\/h3\u003e\n\n\u003ch3\u003ePower Distribution\u003c\/h3\u003e\n\n\u003ctable width=\"100%\"\u003e\n\t\u003ctbody\u003e\n\t\t\u003ctr bgcolor=\"#444444\" data-darkreader-inline-bgcolor=\"\" style=\"--darkreader-inline-bgcolor: var(--darkreader-background-444444, #33373a);\"\u003e\n\t\t\t\u003cth width=\"38%\"\u003e\u003cfont color=\"#ffffff\" data-darkreader-inline-color=\"\" style=\"--darkreader-inline-color: var(--darkreader-text-ffffff, #e8e6e3);\"\u003eSpecification\u003c\/font\u003e\u003c\/th\u003e\n\t\t\t\u003cth\u003e\u003cfont color=\"#ffffff\" data-darkreader-inline-color=\"\" style=\"--darkreader-inline-color: var(--darkreader-text-ffffff, #e8e6e3);\"\u003eDetails\u003c\/font\u003e\u003c\/th\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\" data-darkreader-inline-bgcolor=\"\" style=\"--darkreader-inline-bgcolor: var(--darkreader-background-f2f2f2, #1f2223);\"\u003e\n\t\t\t\u003ctd\u003ePDU Type\u003c\/td\u003e\n\t\t\t\u003ctd\u003eBasic Rack PDU\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eNumber of Outlets\u003c\/td\u003e\n\t\t\t\u003ctd\u003e8\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\" data-darkreader-inline-bgcolor=\"\" style=\"--darkreader-inline-bgcolor: var(--darkreader-background-f2f2f2, #1f2223);\"\u003e\n\t\t\t\u003ctd\u003eOutlet Type\u003c\/td\u003e\n\t\t\t\u003ctd\u003e8 × IEC 60320 C13\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eInput Connection\u003c\/td\u003e\n\t\t\t\u003ctd\u003eIEC 60320 C14\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\" data-darkreader-inline-bgcolor=\"\" style=\"--darkreader-inline-bgcolor: var(--darkreader-background-f2f2f2, #1f2223);\"\u003e\n\t\t\t\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\t\t\t\u003ctd\u003e120 V \/ 208 V \/ 230 V\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\t\t\t\u003ctd\u003e100-240 V\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\" data-darkreader-inline-bgcolor=\"\" style=\"--darkreader-inline-bgcolor: var(--darkreader-background-f2f2f2, #1f2223);\"\u003e\n\t\t\t\u003ctd\u003eMaximum Line Current\u003c\/td\u003e\n\t\t\t\u003ctd\u003e15 A\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eMaximum Input Current\u003c\/td\u003e\n\t\t\t\u003ctd\u003e15 A at 120 V \/ 10 A at 220-240 V\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\" data-darkreader-inline-bgcolor=\"\" style=\"--darkreader-inline-bgcolor: var(--darkreader-background-f2f2f2, #1f2223);\"\u003e\n\t\t\t\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\t\t\t\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eOverload Protection\u003c\/td\u003e\n\t\t\t\u003ctd\u003eResettable Circuit Breaker\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e\u003cimg src=\"https:\/\/www.lockstok.com\/\/ProductImages\/APC\/F1224C0D-CE2F-46DC-8A33-6D449AF2E2E7_428502.jpg?1789634473600\"\u003e\u003c\/h3\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\n\u003ctable width=\"100%\"\u003e\n\t\u003ctbody\u003e\n\t\t\u003ctr bgcolor=\"#444444\" data-darkreader-inline-bgcolor=\"\" style=\"--darkreader-inline-bgcolor: var(--darkreader-background-444444, #33373a);\"\u003e\n\t\t\t\u003cth width=\"38%\"\u003e\u003cfont color=\"#ffffff\" data-darkreader-inline-color=\"\" style=\"--darkreader-inline-color: var(--darkreader-text-ffffff, #e8e6e3);\"\u003eSpecification\u003c\/font\u003e\u003c\/th\u003e\n\t\t\t\u003cth\u003e\u003cfont color=\"#ffffff\" data-darkreader-inline-color=\"\" style=\"--darkreader-inline-color: var(--darkreader-text-ffffff, #e8e6e3);\"\u003eDetails\u003c\/font\u003e\u003c\/th\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\" data-darkreader-inline-bgcolor=\"\" style=\"--darkreader-inline-bgcolor: var(--darkreader-background-f2f2f2, #1f2223);\"\u003e\n\t\t\t\u003ctd\u003eBrand\u003c\/td\u003e\n\t\t\t\u003ctd\u003eAPC\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eManufacturer\u003c\/td\u003e\n\t\t\t\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\" data-darkreader-inline-bgcolor=\"\" style=\"--darkreader-inline-bgcolor: var(--darkreader-background-f2f2f2, #1f2223);\"\u003e\n\t\t\t\u003ctd\u003eProduct Family\u003c\/td\u003e\n\t\t\t\u003ctd\u003eAPC NetShelter\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eProduct Name\u003c\/td\u003e\n\t\t\t\u003ctd\u003eAPC NetShelter Basic Rack PDU\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\" data-darkreader-inline-bgcolor=\"\" style=\"--darkreader-inline-bgcolor: var(--darkreader-background-f2f2f2, #1f2223);\"\u003e\n\t\t\t\u003ctd\u003eManufacturer Part Number\u003c\/td\u003e\n\t\t\t\u003ctd\u003eAP6015A\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eProduct Type\u003c\/td\u003e\n\t\t\t\u003ctd\u003ePower Distribution Unit (PDU)\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\" data-darkreader-inline-bgcolor=\"\" style=\"--darkreader-inline-bgcolor: var(--darkreader-background-f2f2f2, #1f2223);\"\u003e\n\t\t\t\u003ctd\u003ePDU Classification\u003c\/td\u003e\n\t\t\t\u003ctd\u003eBasic\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eRack Mounting\u003c\/td\u003e\n\t\t\t\u003ctd\u003e0U Vertical \/ 1U Horizontal\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\" data-darkreader-inline-bgcolor=\"\" style=\"--darkreader-inline-bgcolor: var(--darkreader-background-f2f2f2, #1f2223);\"\u003e\n\t\t\t\u003ctd\u003eRack Height\u003c\/td\u003e\n\t\t\t\u003ctd\u003e1U when Horizontally Mounted\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eNumber of Outlets\u003c\/td\u003e\n\t\t\t\u003ctd\u003e8\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\" data-darkreader-inline-bgcolor=\"\" style=\"--darkreader-inline-bgcolor: var(--darkreader-background-f2f2f2, #1f2223);\"\u003e\n\t\t\t\u003ctd\u003eOutlet Standard\u003c\/td\u003e\n\t\t\t\u003ctd\u003eIEC 60320 C13\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eInput Connection\u003c\/td\u003e\n\t\t\t\u003ctd\u003eIEC 60320 C14\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\" data-darkreader-inline-bgcolor=\"\" style=\"--darkreader-inline-bgcolor: var(--darkreader-background-f2f2f2, #1f2223);\"\u003e\n\t\t\t\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\t\t\t\u003ctd\u003e120 V \/ 208 V \/ 230 V\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\t\t\t\u003ctd\u003e100-240 V\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\" data-darkreader-inline-bgcolor=\"\" style=\"--darkreader-inline-bgcolor: var(--darkreader-background-f2f2f2, #1f2223);\"\u003e\n\t\t\t\u003ctd\u003eMaximum Line Current\u003c\/td\u003e\n\t\t\t\u003ctd\u003e15 A\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eMaximum Current - 220-240 V\u003c\/td\u003e\n\t\t\t\u003ctd\u003e10 A\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\" data-darkreader-inline-bgcolor=\"\" style=\"--darkreader-inline-bgcolor: var(--darkreader-background-f2f2f2, #1f2223);\"\u003e\n\t\t\t\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\t\t\t\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003ePower Cord Length\u003c\/td\u003e\n\t\t\t\u003ctd\u003e2.5 m\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\" data-darkreader-inline-bgcolor=\"\" style=\"--darkreader-inline-bgcolor: var(--darkreader-background-f2f2f2, #1f2223);\"\u003e\n\t\t\t\u003ctd\u003eColour\u003c\/td\u003e\n\t\t\t\u003ctd\u003eBlack\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eHeight\u003c\/td\u003e\n\t\t\t\u003ctd\u003e4.4 cm\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\" data-darkreader-inline-bgcolor=\"\" style=\"--darkreader-inline-bgcolor: var(--darkreader-background-f2f2f2, #1f2223);\"\u003e\n\t\t\t\u003ctd\u003eWidth\u003c\/td\u003e\n\t\t\t\u003ctd\u003e38.8 cm\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eDepth\u003c\/td\u003e\n\t\t\t\u003ctd\u003e9.3 cm\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\" data-darkreader-inline-bgcolor=\"\" style=\"--darkreader-inline-bgcolor: var(--darkreader-background-f2f2f2, #1f2223);\"\u003e\n\t\t\t\u003ctd\u003eNet Weight\u003c\/td\u003e\n\t\t\t\u003ctd\u003e1.16 kg\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\t\t\t\u003ctd\u003e-5°C to 45°C\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\" data-darkreader-inline-bgcolor=\"\" style=\"--darkreader-inline-bgcolor: var(--darkreader-background-f2f2f2, #1f2223);\"\u003e\n\t\t\t\u003ctd\u003eOperating Relative Humidity\u003c\/td\u003e\n\t\t\t\u003ctd\u003e5% to 95% Non-Condensing\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\t\t\t\u003ctd\u003e0-10,000 ft\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\" data-darkreader-inline-bgcolor=\"\" style=\"--darkreader-inline-bgcolor: var(--darkreader-background-f2f2f2, #1f2223);\"\u003e\n\t\t\t\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\t\t\t\u003ctd\u003e-25°C to 65°C\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eWarranty\u003c\/td\u003e\n\t\t\t\u003ctd\u003e2 Years\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr bgcolor=\"#f2f2f2\" data-darkreader-inline-bgcolor=\"\" style=\"--darkreader-inline-bgcolor: var(--darkreader-background-f2f2f2, #1f2223);\"\u003e\n\t\t\t\u003ctd\u003eEAN \/ GTIN\u003c\/td\u003e\n\t\t\t\u003ctd\u003e0731304327790\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eUPC\u003c\/td\u003e\n\t\t\t\u003ctd\u003e731304327790\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWhat's Included:\u003c\/h3\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e1 × APC NetShelter Basic Rack PDU AP6015A\u003c\/li\u003e\n\t\u003cli\u003eRack Mounting Brackets\u003c\/li\u003e\n\t\u003cli\u003eInstallation Guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003ePlease Note:\u003c\/strong\u003e The AP6015A is a \u003cstrong\u003eBasic Rack PDU\u003c\/strong\u003e intended for power distribution. It does not provide the network monitoring, remote outlet switching or per-outlet metering capabilities found on APC's more advanced managed and switched Rack PDU models.\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eAPC NetShelter Basic Rack PDU AP6015A\u003c\/strong\u003e provides a compact and flexible solution for distributing power to rack-mounted IT equipment, combining eight IEC C13 outlets, 0U\/1U mounting flexibility and a wide 100-240 V input range for server rooms, network cabinets and data centre environments.\u003c\/p\u003e\n","brand":"FirstShop","offers":[{"title":"Default Title","offer_id":53488739975535,"sku":"AP6015A","price":2099.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0457\/5893\/9300\/files\/ap6015a-power-adapters-inverters-1259085773.jpg?v=1789641279","url":"https:\/\/www.firstshop.co.za\/products\/apc-ap6015a-8-ac-outlet-0u-1u-pdu-406365","provider":"FirstShop","version":"1.0","type":"link"}