HP PDU - power distribution strip - 3680 VA
SKU: 252663-B24
Limited or No Stock
Manufacturer: HP
R 6,184.27
R 7,050.06 Incl VAT

From
R 662
per month
Mobicred is a SIMPLE & CONVENIENT credit facility that allows you to SAFELY shop online at all retail partners that offer the mobicred payment option
Request Quote Speak To FirstShop Consultant Chat To FirstShop Consultant Unless otherwise stated in the manufacturer's documentation, all goods delivered to a South African address carry a 12-month manufacturer's warranty. Customers who wish to make a warranty claim must comply with the manufacturer's instructions and warranty procedure. In order to resolve your problem as quickly as possible, we may refer you to the product manufacturer who will deal directly with the return. In these instances, we will provide you with the contact information for the relevant manufacturer. If you are a consumer, this does not affect your statutory rights In the event that First Shop, at its discretion agrees to accept the return for credit of unwanted products, the goods must be returned with First Shop's prior written agreement within 14 days of delivery. The goods must be unopened and in perfect re-saleable condition. All goods returned in these circumstances will be subject to a handling fee of 15% of First Shop's sale price for the goods, or R250, whichever is the greater. Subject to testing to verify any alleged fault, we will accept the return of defective goods for full refund or replacement at our option, if, but only if, the goods are returned within 14 days of delivery. Consumers who wish to return defective products are not obliged to follow the processes set out below, but are recommended to do so as this helps us to provide a more efficient returns service. Some manufacturers require goods to be returned within 14 days or less in order to secure refund. In such instances the manufacturer's time limit will apply and therefore First Shop will only accept a return within 14 days of purchase or the manufacturer's time limit, if that limit is less than 14 days. This is clearly indicated on the catalogue page for the particular product. We can only accept the return of a defective product that does not meet the description, if they are returned to us within 14 days. Beyond that period you will be deemed to have accepted the goods and you must therefore check the goods promptly on receipt. Please note that this period is reduced to 7 days for clearance bargain Promotions/Deals FirstShop
Accessories

Overview

HP PDU - power distribution - 252663-B24

Is your data center lacking sufficient outlet receptacles or flexibility in rack space? Is cable management a problem? HP Modular PDUs have a unique architecture designed specifically for data center customers who want to maximize power distribution and space efficiencies in the rack. Available in a small form factor with flexible mounting options, installation is quick and easy with all brackets, accessories and installation guides included. Modular PDUs consist of two building blocks the Core Unit (core) and the Extension Bar(s) (sticks). The Core Unit is 1U/0U, and the Extension Bars mount directly to the frame of the rack in multiple locations. Single phase models are available up to 40 amps and can have up to 28 outlets divided across 4 extension bars. Three phase models are core only units with 6 x C19 outlets that can be connected to optional extension bars or directly to components such as BladeSystems enclosures.
  • Unique modular design architecture
    HP Modular PDUs modular design architecture with flexible mounting options is designed for data centers with limited space and outlets.
    HP Modular PDUs ship with up to 4 extension bars that can be plugged into the Core Unit and can be mounted directly to the rack-frame or the rack extension unit.
    The HP Modular PDUs are quick and easy to install with all brackets, accessories and installation guides included. Power cords are attached for quick installation.
    The HP Modular PDUs allows for consolidation of cords making cord management easy and efficient. All of the HP Modular PDUs offer superior cable management and accessibility.
    HP Modular PDUs single phase models are available up to 40 amps and can have up to 28 outlets divided across 4 extension bars. Three phase models are core only units with 6 x C19 outlets that can be connected to optional extension bars or directly to components such as BladeSystems enclosures.
  • Horizontal/Modular PDU Models Can be Installed in any U Position in Your Rack
    HPE Basic Power Distribution Units have of a wide range of single and three-phase options providing up to 22kVA of output power.
    Can be installed in any U position in the rack.
    Horizontal/Modular models allow for flexible configuration of power outlets in your rack.
  • Vertical PDU Models use Button and Keyhole Mounting for Simple Drop in Install
    HPE Basic Power Distribution Units vertical form factor models have a wide range of single and three-phase options providing up to 19.9kVA of output power.
    Mounts vertically on either side in the rear of the rack using industry standard button and keyhole mounting.
    Standard mounting faces the outlet towards the rear of the rack preventing interference in the maintenance zone between rear RETMA rails.
    Using the optional configuration of facing the outlets into the rack, multiple PDUs can be mounted on one side of the rack for higher power density.
  • The Reliable Choice
    HPE Foundation Care services purchased for servers extend to our rack and power infrastructure products so you don't have to spend additional budget to cover your infrastructure.
    Designed and tested with HPE servers and storage products. Take advantage of server and IP-based tools used for maintaining and managing all the equipment in the rack.
    HPE can help to simplify IT purchasing, installation, usage, and maintenance for your organization by providing a single point of contact for all your needs.

Tech Specs
Product DescriptionHPE - power distribution strip - 3680 VA
Device TypePower distribution strip - rack-mountable
Weight8.2 kg
Input VoltageAC 200/240 V
Power Capacity3680 VA
Input Connectors1 x power IEC 60320 C20
Output connectors16 x power IEC 60320 C13
Dimensions (WxDxH)44.5 cm x 14.2 cm x 4.1 cm
Manufacturer Warranty3 years warranty
Designed ForHPE 10XXX G2; BladeSystem bc1000; Enterprise Modular Library 71e LTO-4; ProLiant DL320e Gen8, DL360e Gen8, DL360p Gen8, DL380 G6, DL380e Gen8, DL380p Gen8, DL385p Gen8, DL560 Gen8, ML310e Gen8, ML350e Gen8, Moonshot Server, Moonshot Server Starter System, SL250s Gen8, SL270s Gen8, SL390s G7; Rack